Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

UTS-1835
QWERTY123

If you have have configured SSL access to the Monitoring Station, any dashboard content that passes a non-secure URL (such as the Display URL gadget, or the NetFlow dashboard) will not render. This is because the default security preferences in your browser do not allow a mix of protocols (https for the Monitoring Station, and http for rendered content).

Workaround: When this occurs, click the security-related icon in your Monitoring Station browser's address bar, and allow all content to be displayed. You may also be able to load the browser with arguments that does this on start-up (for example, using the --allow-running-insecure-content parameter on Chrome).

UTS-1827
QWERTY123
When upgrading from version 7.2 on Windows, you will see gadget-related entries in the up.time logs that indicate errors during the update process. Note that these are, in fact, non-issues, and as steps carried out later in the upgrade process perform these steps successfully.
UTS-1825When configuring the File System Capacity monitor, incorrectly defined special cases that are rejected are not being retained in the configuration window so that you can refine them.
UTS-1707If a service outage enters a MAINT state, it will incorrectly receive a new incident number.

...