Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

FieldTypeDescription
descriptionStringDescription of this Element.
groupIdIntegerID for this Element's parent Element group.
hostnameStringHostname used to contact this Element.
idIntegerID for this Element.
isMonitoredBooleanMonitoring status for this Element.
monitorsArrayAn array listing all monitors that belong to this Element (see Monitors Array below for details).
nameStringThe display name of this Element.
tagsArrayAn array listing all views/tags that this Element belongs to (see Tags Array below for details).
topologicalChildrenArrayAn array listing all Elements that are a topological dependency of this Element in up.time Uptime Infrastructure Monitor (see Topological Children Array below for details).
topologicalParentsArrayAn array listing all Elements that are topological parents of this Element in up.time Uptime Infrastructure Monitor (see Topological Parents Array below for details).
typeNameString

A basic type definition for the Element. The following types are supported:

  • server
  • network device
  • Application
typeOsString

Returns basic operating system information for this Element:

  • server: operating system
  • network device: sysDescr value
  • Application: no result is returned

Elements of other types are not currently supported by the API.

typeSubtypeString

Basic type information for this Element. This value should be used for matching Elements based on subtype. The following subtypes are supported:

  • server
    • AIX
    • Linux
    • Netware
    • Solaris
    • Windows
    • Hpux
    • EsxServer
    • IbmPowerSystems
    • VcenterServer
    • VcenterHostSystem
    • Unknown
  • network device
    • switch
  • Application
    • Application
typeSubtypeNameString

Detailed descriptions of the subtype, ideally used for display purposes. The values provided for this field are open to change and should not be used for matching purposes.

...

FieldTypeDescription
elementIdIntegerID of the Element this monitor is related to
idIntegerID of the service monitor
isHiddenBooleanhidden monitors are internal monitors that up.time Uptime Infrastructure Monitor uses, and can be ignored
isMonitoredBooleanmonitoring status for the service monitor
nameStringname of the service monitor

...

FieldTypeDescription
descriptionStringDescription of this Element.
groupIdIntegerID for this Element's parent Element group.
hostnameStringHostname used to contact this Element.
idIntegerID for this Element.
isMonitoredBooleanMonitoring status for this Element.
monitorsArrayAn array listing all monitors that belong to this Element (see Monitors Array below for details).
nameStringThe display name of this Element.
tagsArrayAn array listing all views/tags that this Element belongs to (see Tags Array below for details).
topologicalChildrenArrayAn array listing all Elements that are a topological dependency of this Element in up.time Uptime Infrastructure Monitor (see Topological Children Array below for details).
topologicalParentsArrayAn array listing all Elements that are topological parents of this Element in up.time Uptime Infrastructure Monitor (see Topological Parents Array below for details).
typeNameString

A basic type definition for the Element. The following types are supported:

  • server
  • network device
  • Application
typeOsString

Returns basic operating system information for this Element:

  • server: operating system
  • network device: sysDescr value
  • Application: no result is returned

Elements of other types are not currently supported by the API.

typeSubtypeString

Basic type information for this Element. This value should be used for matching Elements based on subtype. The following subtypes are supported:

  • server
    • AIX
    • Linux
    • Netware
    • Solaris
    • Windows
    • Hpux
    • EsxServer
    • IbmPowerSystems
    • VcenterServer
    • VcenterHostSystem
    • Unknown
  • network device
    • switch
  • Application
    • Application
typeSubtypeNameString

Detailed descriptions of the subtype, ideally used for display purposes. The values provided for this field are open to change and should not be used for matching purposes.

...

FieldTypeDescription
elementIdIntegerID of the Element this monitor is related to
idIntegerID of the service monitor
isHiddenBooleanhidden monitors are internal monitors that up.time Uptime Infrastructure Monitor uses, and can be ignored
isMonitoredBooleanmonitoring status for the service monitor
nameStringname of the service monitor

...

Response Code

Code Description

HTTP Status Code

Details

 OK200Information retrieved successfully.
UT-1000Element Does Not Exist404

A specifically referenced Element ID does not exist.

In such a case, referencing https://youruptime:9997/api/v1/elements/12345 would return the following:

The element id '12345' does not exist.

The Element ID endpoint may be omitted, was inputted incorrectly, or is ignored in upUptime Infrastructure Monitor.time.

UT-1010Element Filter Expired410

The filter you are referencing is expired. Created filters persist, by default, for five minutes.

UT-1012Element Group Filter Expired410The group filter you are referencing is expired. Created filters persist, by default, for five minutes.
UT-1013Invalid Element Filter400The JSON used to create an Element filter is invalid, and could not be parsed. Check to ensure you are posting well-formed JSON.
UT-1015Invalid Element Group Filter400The JSON used to create an Element group filter is invalid, and could not be parsed. Check to ensure you are posting well-formed JSON.
UT-1028URL ID Body Mismatch400The Element ID in the URL and the JSON object do not match.

...

FieldTypeDescription
elementIdIntegerID of the Element this monitor is related to
idIntegerID of the service monitor
isHiddenBooleanhidden monitors are internal monitors that up.time Uptime Infrastructure Monitor uses, and can be ignored
isMonitoredBooleanmonitoring status for the service monitor
nameStringname of the service monitor
messageStringthe output message produced the last time the service monitor was executed
statusStringthe last known status of this service monitor
lastCheckTimeString - Date Timethe last time this service monitor was executed successfully
lastTransitionTimeString - Date Timethe last time this service monitor changed status; this field can be used to determine time in the current status

...

Response Code

Code Description

HTTP Status Code

Details

 OK200Information retrieved successfully.
UT-1000Element Does Not Exist404

A specifically referenced Element ID does not exist.

In such a case, referencing https://youruptime:9997/api/v1/elements/12345 would return the following:

The element id '12345' does not exist.

The Element ID endpoint may be omitted, was inputted incorrectly, or is ignored in up.timeUptime Infrastructure Monitor.

UT-1010Element Filter Expired410

The filter you are referencing is expired. Created filters persist, by default, for five minutes.

UT-1012Element Group Filter Expired410The group filter you are referencing is expired. Created filters persist, by default, for five minutes.
UT-1013Invalid Element Filter400The JSON used to create an Element filter is invalid, and could not be parsed. Check to ensure you are posting well-formed JSON.
UT-1015Invalid Element Group Filter400The JSON used to create an Element group filter is invalid, and could not be parsed. Check to ensure you are posting well-formed JSON.
UT-1028URL ID Body Mismatch400The Element ID in the URL and the JSON object do not match.

...

PropertyDescriptionRequirements
idthe id of the Element you want to update
  • required property
  • must match an Element ID
namedisplay name for the Element anywhere in the up.time Uptime Infrastructure Monitor Web interface
  • must be unique
  • maximum 50 characters
descriptiondescription for the Element
  • maximum 255 characters
hostnameresolvable network hostname or IP address of the Element
  • must be unique 
  • maximum 255 characters 
  • contains no whitespace characters
groupIdthe Element Group to which the Element belongs
  • must match valid groupId
  • end-user's user group is able to see the Element group
isMonitoredenables and disables monitoring for the Element, determining whether it appears in Global Scan and other dashboards
  • must be Boolean
Notes

In up.timeUptime Infrastructure Monitor, vCenter-based Elements (specifically, VMs and ESX hosts) are typically managed via vSync. This synchronization includes an Element's display name and hostname. Modifying either property through the API automatically disables its synchronization. Re-enabling the property must be done manually through the up.time Uptime Infrastructure Monitor Web interface (using the Element's Sync Display Name and Sync Hostname option).

...

Response Code

Code Description

HTTP Status Code

Details

UT-0200OK200Operation performed successfully.
UT-1000Element Does Not Exist404

A specifically referenced Element ID does not exist.

In such a case, referencing https://youruptime:9997/api/v1/elements/12345 would return the following:

The element id '12345' does not exist.

The Element ID endpoint may be omitted, was inputted incorrectly, or is ignored in upUptime Infrastructure Monitor.time.

UT-1002Element Group Does Not Exist400The referenced group ID does not exist.
UT-1025Invalid Request Body JSON400The JSON object is not well formed.
UT-1028URL ID Body Mismatch400The Element ID in the URL and the JSON object do not match.
UT-1029Duplicate Hostname200Another Element (which you may not have permission to view) already exists with this hostname.
UT-1030Duplicate Element Name200Another Element (which you may not have permission to view) already exists with this display name.
UT-1033License Violation400Setting this Element to isMonitored exceeds the current license.
UT-1040Spaces in Hostname

n/a
(JSON validation)

The Element hostname cannot contain whitespace.
UT-1041Proxy Error400This error can occur when your deployment includes a UI instance.
UT-1042HMC Violation400This error can occur when updating a pSeries-based Element that uses the HMC.
UT-1043Missing Fieldn/a
(JSON validation)
One or more of the Element ID, name, or hostname is missing.
UT-1044Field Number out of Range

n/a
(JSON validation)

The declared Element group ID needs to be equal to or greater than 1.
UT-1045Field Too Long

n/a
(JSON validation)

One or more of the Element's name, description, or hostname exceed the maximum number of characters.

...

PropertyDescriptionRequirements
namedisplay name for the Element anywhere in the up.time Uptime Infrastructure Monitor Web interface
  • required property
  • must be unique
  • maximum 50 characters
descriptionoptional description for the Element
  • maximum 255 characters
hostnameresolvable network hostname or IP address of the Element
  • required property
  • must be unique 
  • maximum 255 characters 
  • contains no whitespace characters
groupIdthe Element Group the Element is placed in upon creation
  • required property
  • must match valid groupId
  • end-user's user group is able to see the Element group
type

the basic Element type:

  • Server
  • Network Device
  • required property
  • must match one of the basic Element types (in this case, Server)
collectionMethodarray of data-collection properties describing how up.time Uptime Infrastructure Monitor communicates with the Element
  • required property
connectionType

the connection method for the Element:

  • agent
  • wmi
  • snmp
  • required property
  • must match one of the Element connection methods (in this case, agent)
useGlobalConnectionSettings

Boolean determining whether the up.time Uptime Infrastructure Monitor Agent Global Configuration is enabled in Global Element Settings

if true, all other connection properties are ignored

  • defaults to false if property is not defined
portthe port through which the up.time Uptime Infrastructure Monitor Agent communicates with the Monitoring Station
  • required if useGlobalConnectionSettings property is false
  • must be a valid port number (default 9998)
useSSLBoolean indicating whether the up.time Uptime Infrastructure Monitor Agent securely communicates with the Monitoring Station using SSL
  • required if useGlobalConnectionSettings property is false
  • must be Boolean

...

Example

Add a server that has an up.time Uptime Infrastructure Monitor Agent installed for data collection:

...

FieldDescriptionRequirements
namedisplay name for the Element anywhere in the up.time Uptime Infrastructure Monitor Web interface
  • required property
  • must be unique
  • maximum 50 characters
descriptionoptional description for the Element
  • maximum 255 characters
hostnameresolvable network hostname or IP address of the Element
  • required property
  • must be unique 
  • maximum 255 characters 
  • contains no whitespace characters
groupIdthe Element Group the Element is placed in upon creation
  • required property
  • must match valid groupId
  • end-user's user group is able to see the Element group
type

the basic Element type:

  • Server
  • Network Device
  • required property
  • must match one of the basic Element types (in this case, Server)
collectionMethodarray of data-collection properties describing how up.time Uptime Infrastructure Monitor communicates with the Element
  • required property
connectionType

the connection method for the Element:

  • agent
  • wmi
  • snmp
  • required property
  • must match one of the Element connection methods (in this case, wmi)
useGlobalConnectionSettings

Boolean determining whether the up.time Uptime Infrastructure Monitor Agent Global Configuration is enabled in Global Element Settings

if true, all other connection properties are ignored

  • defaults to false if property is not defined
wmiDomainthe Windows domain in which WMI is implemented
  • required if useGlobalConnectionSettings property is false
wmiUsernamethe name of the account with access to WMI on the Windows domain
  • required if useGlobalConnectionSettings property is false
wmiPassword

the password for the username above

Info

the plain-text password is passed to up.time Uptime Infrastructure Monitor using an encrypted connection

  • required if useGlobalConnectionSettings property is false

...

FieldDescriptionRequirements
namedisplay name for the Element anywhere in the up.time Uptime Infrastructure Monitor Web interface
  • required property
  • must be unique
  • maximum 50 characters
descriptionoptional description for the Element
  • maximum 255 characters
hostnameresolvable network hostname or IP address of the Element
  • required property 
  • must be unique 
  • maximum 255 characters 
  • contains no whitespace characters
groupIdthe Element Group the Element is placed in upon creation
  • required property
  • must match valid groupId
  • end-user's user group is able to see the Element group
type

the basic Element type:

  • Server
  • Network Device
  • required property
  • must match one of the basic Element types (in this case, Server)
collectionMethodarray of data-collection properties describing how up.time Uptime Infrastructure Monitor communicates with the Element
  • required property
connectionType

the connection method for the Element:

  • agent
  • wmi
  • snmp
  • required property
  • must match one of the Element connection methods (in this case, snmp)
useGlobalConnectionSettings

Boolean determining whether Global SNMP Configuration Settings are set in Global Element Settings

if true, all other connection properties are ignored

  • defaults to false if property is not defined
snmpVersion

the SNMP version used to connect to the network device:

  • v2
  • v3
  • required if useGlobalConnectionSettings is false
  • must match one of the valid SNMP versions (in this case, v2)
snmpPortthe port on which the device is listening
  • required if useGlobalConnectionSettings is false
  • must be a valid port number (default 161)
snmpV2ReadCommunitythe SNMP community to use for the connection, typically set to public
  • required if useGlobalConnectionSettings is false
isPingabledetermines whether up.time Uptime Infrastructure Monitor can contact the device using the ping utility
  • required if useGlobalConnectionSettings is false
  • must be Boolean

...

FieldDescriptionRequirements
namedisplay name for the Element anywhere in the up.time Uptime Infrastructure Monitor Web interface
  • required property
  • must be unique
  • maximum 50 characters
descriptionoptional description for the Element
  • maximum 255 characters
hostnameresolvable network hostname or IP address of the Element
  • required property
  • must be unique 
  • maximum 255 characters 
  • contains no whitespace characters
groupIdthe Element Group the Element is placed in upon creation
  • required property
  • must match valid groupId
  • end-user's user group is able to see the Element group
type

the basic Element type:

  • Server
  • Network Device
  • required property
  • must match one of the basic Element types (in this case, Server)
collectionMethodarray of data-collection properties describing how up.time Uptime Infrastructure Monitor communicates with the Element
  • required property
connectionType

the connection method for the Element:

  • agent
  • wmi
  • snmp
  • required property
  • must match one of the Element connection methods (in this case, snmp)
useGlobalConnectionSettings

Boolean determining whether Global SNMP Configuration Settings are set in Global Element Settings

if true, all other connection properties are ignored

  • defaults to false if property is not defined
snmpVersion

the SNMP version used to connect to the network device:

  • v2
  • v3
  • required property
  • must match one of the valid SNMP versions (in this case, v3)
snmpPortthe port on which the device is listening
  • required if useGlobalConnectionSettings is false
  • must be a valid port number (default 161)
snmpV3Usernamethe name required to connect to the network device
  • required if useGlobalConnectionSettings is false
snmpV3AuthenticationPassword

the password required to connect to the network device

Info

the plain-text password is passed to up.time Uptime Infrastructure Monitor using an encrypted connection

  • required if useGlobalConnectionSettings is false
snmpV3AuthenticationMethod

determines how encrypted data moving between the network device and up.time Uptime Infrastructure Monitor is authenticated:

  • MD5
  • SHA
  • required if useGlobalConnectionSettings is false
  • must match one of the valid authentication methods
snmpV3PrivacyPassword

the password used to encrypt data moving between the network device and up.timeUptime Infrastructure Monitor

Info

the plain-text password is passed to up.time Uptime Infrastructure Monitor using an encrypted connection

  • required if useGlobalConnectionSettings is false
snmpV3PrivacyType

determines how data moving between the network device and up.time Uptime Infrastructure Monitor is encrypted:

  • DES
  • AES
  • required if useGlobalConnectionSettings is false
  • must match one of the valid privacy types
isPingabledetermines whether up.time Uptime Infrastructure Monitor can contact the device using the ping utility
  • required if useGlobalConnectionSettings is false
  • must be Boolean

...

vCenter-based Elements mirrored in up.time Uptime Infrastructure Monitor via vSync cannot be deleted, only ignored:

...

Response Code

Code Description

HTTP Status Code

Details

 No Content204Operation performed successfully.
UT-1000Element Does Not Exist404

A specifically referenced Element ID does not exist.

In such a case, referencing https://youruptime:9997/api/v1/elements/12345 would return the following:

The element id '12345' does not exist.

The Element ID endpoint may be omitted, was inputted incorrectly, or is ignored in up.timeUptime Infrastructure Monitor.

UT-1025Invalid Request Body JSON400The JSON object is not well formed.
UT-1026VM Not Deleted403

VMs and ESX hosts that are ignored cannot be deleted.

UT-1027Element Not Deleted403You are trying to delete an ESX host that is part of a cluster.
UT-1032Manual Monitor Not Deleted403Manually monitored hosts cannot be deleted.

...

DELETE https://youruptime/api/v1/elements/16