Overview

up.time Uptime Infrastructure Monitor collects the configuration and performance data outlined in this article from Net-SNMP implementations. Additional performance data outside of this set can be collected using the SNMP service monitor with retained performance metrics.  If you haven't already please review How to add a Net-SNMP enabled server to Uptime Infrastructure Monitor

List of Required Net-SNMP MIBs

All data that up.time Uptime Infrastructure Monitor gathers from Net-SNMP is based on the following MIB implementations:

...

MetricExplanationSource MIB
sysNameThe name of the system on which Net-SNMP is running.RFC 1213 - sysName
sysDescThe hardware architecture of the system.RFC 1213 - sysDesc
hrDeviceTableup.time Uptime Infrastructure Monitor uses the following information returned by this metric: the number of CPUs on the system and the CPU configuration.HOST-RESOURCES-MIB - hrDeviceTable.
memTotalRealThe amount of memory available on the system.UCD-SNMP-MIB - memTotalReal
memTotalSwapThe size of swap space available on the system.UCD-SNMP-MIB - memTotalSwap
ifDescrThe name of the network card that is installed on the system.RFC 1213 - interfaces/ifDescr
ifMtuThe largest amount of data that the network interface can transmit in a single physical frame.RFC 1213 - interfaces/ifMtu
ifSpeedThe maximum speed of the network interface.RFC 1213 - interfaces/ifSpeed
ifPhysAddressThe physical address of the network interface.RFC 1213 - interfaces/ifPhysAddress

...