Problem
When performing the default ping check for a host, up.time Uptime Infrastructure Monitor may display an error message similar to the following:
IO
...
Exception:
...
CreateProcess:
...
C:/Program
...
Files/uptime4/externalApps/win32/icmp.exe
...
icmp.exe
...
filter
...
1
...
error=2
Solution
Panel |
---|
|
To correct this error, take the following steps: - Open the uptime.conf file in a text editor.
- Look for the following entry:
externalErdcScriptPath=<install_dir>/bin/
This is the path in which up.time Uptime Infrastructure Monitor searches for executables, specifically icmp.exe and lmhostid.exe. Note that<install_dir> is the directory in which up.time Uptime Infrastructure Monitor is installed. If you installed up.time Uptime Infrastructure Monitor in the default location, on Windows this path is C:/Program Files/uptime software/uptime/support/bin/ . - If the
externalErdcScriptPath entry is not in the file, add it to uptime.conf.Otherwise, ensure that the correct <install_dir> is specified. - Stop and restart the up.time Uptime Infrastructure Monitor Data Collector service.
|