Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

If the Uptime Infrastructure Monitor Linux Agent is managed by xinetd (default option), it is possible to limit access to the Agent with xinetd's "only_from" parameter.  Setting only_from parameter to the Uptime Infrastructure Monitor Monitoring Station hostname or IP address will restrict any other system from issuing requests to the Uptime Infrastructure Monitor Agent.

 

To implement, update the /etc/xinetd.d/uptimeagent configuration file and add the following line at the end (above the closing curly bracket).

Code Block
languagetext
only_from = uptime_ms


If using an IP address, the only_from line is similar:

Code Block
languagetext
only_from = 10.1.1.1


With the /etc/xinetd.d/uptimeagent configuration file updated, restart the xinetd service to read in the change.

Code Block
languagetext
/etc/init.d/xinetd restart

 

Now, only the Uptime Infrastructure Monitor Monitoring Station system can access the Uptime Infrastructure Monitor Agent.